目录产品使用需知.........................................................................................................................................I一、监控模块........................................................................................................................................1NT8265单常开防火门监控模块..........................................................................................................1NT8266单常闭防火门监控模块..........................................................................................................2NT8267双常开防火门监控模块..........................................................................................................3NT8268双常闭防火门监控模块..........................................................................................................4二、监控系统........................................................................................................................................6NT8051防火门监控器..........................................................................................................................6NT8052电源箱......................................................................................................................................8LL1003手持编址器..............................................................................................................................9三、防火门电动闭门器......................................................................................................................10GA93-3CⅢ(LELE-FWD)电动闭门器.............................................................................................10四、门磁开关......................................................................................................................................12MC-57门磁开关..................................................................................................................................12五、综合防火门系统设计..................................................................................................................14产品使用需知一、产品布线要求1、防火门监控器或电源箱到监控模块之间的连接线防火门监控器或电源箱与监控模块之间的DC24V电源线采用截面积不小于1.5mm2双色双绞耐火铜芯电线电缆,在带满127只模块(其中释放器型常开防火门最多32个或电动闭门器型常开防火门最多64个)的情况下,最远布线长度为200m;DC24V电源线如果采用截面积不小于2.5mm2双色双绞耐火铜芯电线电缆,在带满127只模块(其中释放器型常开防火门最多32个或电动闭门器型常开防火门最多64个)的情况下,最远布线长度为500m。其他情况可以计算得出,基本原则:最末端常开防火门模块的供电电源电压不低于18V。防火门监控器或电源箱与监控模块之间总线采用截面积不小于1.0mm2双色双绞阻燃或阻燃耐火电线电缆,在带满127只防火门监控模块的情况下,最远布线长度为1000m。2、监控模块到电动闭门器、释放器、门磁之间的连接线采用截面积不小于1.5mm2双色双绞耐火铜芯电线电缆,长度不超过5m。3、防火门监控器到电源箱之间的连接线每台防火门监控器最多可以带30台电源箱,防火门监控器与电源箱之间的通讯线采用截面积不小于1.0mm2双色双绞阻燃或阻燃耐火电线电缆,最远布线长度为1000m。连接方式为总线拓扑结构,也就是从A到B,从B到C,从C到D…,A表示防火门监控器,B、C、D。。表示电源箱,且B、C、D…顺序从01、02、03、...对应顺序排列。4、穿管保护要求系统的电源线、总线可以共管铺设,请根据实际工程情况合理布线。但本系统电源线及总线不能与工程现...