方形横流式冷却塔技术参数型号DBHZ冷吨数(RT)冷却水量m3/h外形尺寸(mm)风机电机进塔水压104Pa重量(kg)噪声dB(A)28℃T27℃T25℃TLWHhD(mm)G(m3/h)KW×台数干重湿重80117.980921084320220022647501800471.5×14.41710336854.6100147.41001151364320220026687501800632.2×14.81810360655125189.71251481704620288026688002100732.2×14.82240466055.1150220.5150172204462033602668800210085.83×14.82665565055.1175256.41752002384920346031138502400983×15.22987634055.6200294.920023027249203800311385024001174×15.23205720055.7250379.425028734046205760266880021001462.2×24.84480932056.23004413003444084620672026688002100171.63×24.853301130056.3350512.835040027649206920311385024001963×25.259741268056.7400589.840046054449207600311385024002344×25.264101440057.3450661.545051661246201008026688002100257.43×34.879951695057.1525769.2525600714492010380311385024002943×35.289601902057.1600884.7600690816492011400311385024003514×35.296152160056.67001025.6700800952492013840311385024003923×45.2119482536056.48001179.68009201088492015200311385024004684×45.2128202880056.390013239001032122446202016026688002100514.63×64.815990339005610501538.4105012001428492020760311385024005883×65.2179223804055.812001769.4120013801632492022800311385024007024×65.2192304320055.5技术参数说明:●各湿球温度(T)的冷却水量都是以进水温度t1=37℃,出水温度t2=32℃,水温降△t=5℃的工况,其冷吨数以27℃(T)1RT=3900kkal/h折算的。●进塔水压以基座底面为准,其水压相当于进入配水箱接口的自由水头1.53Pa,即等于1.5米水头。●噪声以进风百叶窗外塔的当量直径远距地面1.5米高的dB(A)值。CDBHZ系列组装式节能超低噪声横流式冷却塔主要参数表型号DBHZ冷吨数(RT)冷却水量m3/h外形尺寸(mm)风机电机进塔水压104Pa重量(kg)噪声dB(A)28℃T27℃T25℃TLWHh2D(mm)G(m3/h)KW×台数干重湿重80117.9809210873202200226420001800471.5×14.42369402748.6100147.410011513673202200266820001800632.2×14.82480427649125189.712514817076202880266820002100732.2×14.83015563049.1150220.51501722047620336026682000210085.83×14.83534652049.1175256.417520023879203460311320002400983×15.23893724549.6200294.9200230272792038003113200024001174×15.24200823049.7250379.4250287340762057602668200021001462.2×24.860301120050.230044130034440876206720266820002100171.63×24.870681304050.3350512.8350400276792069203113200024001963×25.277861449050.7400589.8400460544792760031120024002344×25.28400164651.30300450661.5450516612762010080266820002100257.43×34.8106021956051.1525769.25256007147920103803113200024002943×35.2116792172551.1600884.76006908167920114003113200024003514×35.2126002469050.67001025.67008009527920138403113200024003923×45.2155722608050.48001179.680092010887920152003113200024004684×45.2168003292050.3900132390010321224762020160266820002100514.63×64.8212043912050.210501538.41050120014287920207603113200024005883×65.2233584347050.112001769.41200138016327920228003113200024007024×65.2252004938050技术参数说明:●各湿球温度(T)的冷却水量都是以进水温度t1=37℃,出水温度t2=32℃,水温降△t=5℃的工况,其冷吨数以27℃(T)1RT=3900kkal/h折算的。●进塔水压以基座底面为准,其水压相当于进入配水箱接口的自由水压1.53Pa,即等于1.5米水头。●噪声以遮声板外塔的当量直径远,不计遮声面积,距地面1.5米高的dB(A)值。以上技术只是有www.wylqt.com提供