长沙医学院毕业设计(论文)课题名称POCT血糖仪与Au5800生化分析仪的比对评估分析学生姓名唐宝宝学号院(系)、年级专业医学检验系13级医学检验技术2班指导教师林雪迟刘志敏职称教授主管检验技师2017年6月15日目录中文摘要..............................................................................................................Ⅰ英文摘要.............................................................................................................Ⅱ前言.......................................................................................................................1正文.......................................................................................................................31材料与方法.....................................................................................................31.1材料..............................................................................................................3方法.......................................................................................................................32结果....................................................................................................................5三种血糖仪检测结果与偏倚范围.............................................................53款POCT血糖仪与AU5800生化分析仪的相关性分析.....................53款POCT血糖仪与AU5800生化分析仪结果比对的通过率............63讨论......................................................................................................................84结论....................................................................................................10参考文献............................................................................................................11致谢......................................................................................................................13综述.....................................................................................................................14摘要目的:通过便携式血糖仪(POCT)和自动生化分析仪比较血糖比较检测结果,掌握三种POCT血糖仪和生化分析仪的结果。方法:选择血糖浓度分布在1-30mmol的标本5份。每份标本重复测定两次。同时30min内分离血浆在Au5800全自动生化仪进行葡萄糖测定,运用SPSS18.0统计学对结果进行比对综合分析。结果:三种型号血糖仪的比对试验通过率分别为100%,95%,100%。配对t检验显示血糖仪和生化分析仪三种模型差异无统计学意义(P>0.05),相关系数大于0.98,表明相关性良好。三种血糖仪精度符合要求(CV%<7.5%)。结论:100套血糖仪符合中国POCT血糖仪应用指南,但不同类型的仪器和生化结果有一定差异,只能用于血糖监测,不能用作诊断试验。关键词:POCT血糖仪比对评估ABSTRACTOBJECTIVE:Tocomparetheresultsofbloodglucosecomparisontestwithportablebloodglucosemeter(POCT)andautomaticbiochemicalanalyzer,andtomastertheresultsofthreePOCTbloodglucosemeterandbiochemicalanalyzer.Methods:5%ofthesampleswereselectedfrom1to30mmolofbloodglucoseconcentration.Eachspecimenwasrepeatedtwice.Atthesametime,plasmawasseparatedfromtheplasmaintheAu5800automaticbiochemicalanalyzer.TheresultswerecomparedwithSPSS18.0.Results:Thetestpassratesofthethreemodelswere100%,95%and100%,respectively.Thepairedttestshowedthattherewasnosignificantdifferencebetweenthetwomodels(P>0.05),andthecorrelationcoefficientwasmorethan0.98,whichindicatedthatthecorrelationwasgood.Threebloodglucosemetersmeettherequirements(CV%<7.5%).Conclusion:100setsofblood...