精品文档精品文档注:干湿球温度计的准确度等级可不写,最大允许误差为:±2℃/2%压力表允许误差计算值一览表(JJG52-1999)单位:MPa准确度等级测量上限11.62.540.1±0.001±0.0016±0.0025±0.0040.16±0.0016±0.00256±0.004±0.00640.25±0.0025±0.004±0.00625±0.010.4±0.004±0.0064±0.01±0.0160.6±0.006±0.0096±0.015±0.0241±0.01±0.016±0.025±0.041.6±0.016±0.0256±0.04±0.0642.5±0.025±0.04±0.0625±0.14±0.04±0.064±0.1±0.166±0.06±0.096±0.15±0.2410±0.1±0.16±0.25±0.416±0.16±0.256±0.4±0.6425±0.25±0.4±0.625±140±0.4±0.64±1±1.660±0.6±0.96±1.5±2.4100±1±1.6±2.5±4160±1.6±2.56±4±6.4250±2.5±4±6.25±10400±4±6.4±10±16电流表、电压表、功率表和电阻表准确度等级及最大允许误差(JJG124-2005)准确度等级0.10.20.511.52.02.55.01020最大允许误差(%)±0.1±0.2±0.5±1.0±1.5±2.0±2.5±5.0±10±20精品文档精品文档600±6±9.6±15±241000±10±16±25±40精密压力表允许误差计算值一览表(JJG49-1999)单位:MPa准确度等级测量上限0.060.10.160.250.40.60.1±0.000±0.0016±0.00016±0.00025±0.0004±0.00060.16±0.0001±0.00256±0.00026±0.0004±0.00064±0.000960.25±0.0002±0.004±0.0004±0.000625±0.001±0.00150.4±0.000±0.0064±0.00064±0.001±0.0016±0.00240.6±0.000±0.0096±0.00096±0.0015±0.0024±0.00361±0.00±0.016±0.0016±0.0025±0.004±0.0061.6±0.001±0.0256±0.00256±0.004±0.0064±0.00962.5±0.002±0.04±0.004±0.00625±0.01±0.0154±0.00±0.064±0.0064±0.01±0.016±0.0246±0.00±0.096±0.0096±0.015±0.024±0.03610±0.0±0.16±0.016±0.025±0.04±0.0616±0.01±0.256±0.0256±0.04±0.064±0.09625±0.02±0.4±0.04±0.0625±0.1±0.1540±0.0±0.64±0.064±0.1±0.16±0.2460±0.0±0.96±0.096±0.15±0.24±0.36100±0±1.6±0.16±0.25±0.4±0.6160±0.1±2.56±0.256±0.4±0.64±0.96250±0.2±4±0.4±0.625±1±1.5400±0±6.4±0.64±1±1.6±2.4600±0±9.6±0.96±1.5±2.4±3.61000±1±16±1.6±2.5±4±6精品文档精品文档砝码最大允许误差的绝对值(│MPE│)(JJG99-2006)单位:mg标称值E1E2F1F2M1M11M2M22M35000kg2500080000250000500000800000160000025000002000kg10000300001000002000003000006000001000001000kg160050001600050000100000160000300000500000500kg80250800250050008000016000250000200kg30010003000100002000030000100000100kg1605001600500010000160005000050kg25802508002500500080002500020kg1030100300100030001000010kg5.01650160500160050005kg2.58.0258025080025002kg1.03.0103010030010001kg0.51.65.01650160500500g0.250.82.58.02580250200g0.100.31.03.01030100100g0.050.160.51.65.0165050g0.030.100.31.03.0103020g0.0250.080.250.82.58.02510g0.0200.060.200.62.06.0205g0.0160.050.160.51.65.0162g0.0120.040.120.41.24.0121g0.0100.030.100.31.03.010500mg0.0080.0250.080.250.82.5200mg0.0060.020.060.20.62100mg0.0050.0160.050.160.51.650mg0.0040.0120.040.120.420mg0.0030.0100.030.100.310mg0.0030.0080.0250.080.255mg0.0030.0060.0200.060.20精品文档精品文档2mg0.0030.0060.0200.060.201mg0.0030.0060.0200.060.20通用卡尺示值误差(JJG30-20024.9)单位:mm测量范围分度值(分辨力)0.01,0.020.050.10允许误差0-150±0.02±0.05±0.10>150-200±0.03±0.05±0.10>200-300±0.04±0.08±0.10>300-500±0.05±0.08±0.10>500-1000±0.07±0.10±0.15>1000-1500±0.10±0.15±0.20>1500-2000±0.14±0.20±0.25指针式指示表的最大允许误差和回程误差(JJG34-20084.9表6)单位:mm分度值测量范围上限S最大允许误差(不超过)回程误差任意0.05mm任意0.1mm任意0.2mm任意1mm全量程0.01≤3-0.005-0.0100.0140.0033-5(含)-0.005-0.0100.0160.0035-10(含)-...